Top Quality Fixed X-ray Grid Jpi Fixed X-ray Grid Medical Lead Anti Scatter Grid X Rays

Short Description:

Pixel Pitch 139 μm
Pixel Matrix 7648 x 3072
ADC 16-bit
Gain Stage Multi-Gain
Scintillator GOS
Water Proof IP54
Interface

Gigabit Ethernet

High voltage generator

Power

Calibration Software, Firmware
Radiation Hardness ≥10000Gy

Product Detail

Product Tags

Our products are greatly acknowledged and reliable by users and may fulfill repeatedly shifting financial and social wants for Top Quality Fixed X-ray Grid Jpi Fixed X-ray Grid Medical Lead Anti Scatter Grid X Rays, Aggressive selling price with superior quality and satisfying services make us earned far more consumers.we wish to work along with you and look for common improvement.
Our products are greatly acknowledged and reliable by users and may fulfill repeatedly shifting financial and social wants for China X-ray Grid and X Ray Grid, If any item be of interest to you, make sure you let us know. We’ll try our best to satisfy your requirements with high quality solutions, the best prices and prompt delivery. You should feel free to contact us at any time. We’ll reply you when we receive your inquiries. Please note that samples are available before we start our business.
Whale43100PSM is a portable type and low-noise x-ray flat panel detector based on amorphous silicon technology. A-Si technology-based detector owns many advantages that are unavailable with other technologies. Whale43100PSM can generate both high image quality, and high dynamic range, and possesses a multi-gain stage as a detector requirement. Based on the above characteristics, the Whale43100PSM detector can be suitable for full spine x-ray.

Single shot: captures long-length image in one shot

Rapid: saves time and minimizes patient hold time

Accurate: provides a unified image and avoids overlapping due to patient movement

Friendly:lower doses are more patient friendly

Technology
Sensor A-Si
Scintillator GOS
Active Area 1075 x 430 mm
Pixel Matrix 7648 x 3072
Pixel Pitch  139 μm
AD Conversion 16 bits
Interface
Communication Interface Gigabit Ethernet
Exposure Control  Prepare / Ready / X Ray On(Edge or Level)
Work Mode Software Mode / HVG Trigger Mode / AED Trigger Mode
Image Acquisition Time ≤1 s
Operating System  Windows7 / Windows10 OS 32 bits or 64 bits
Technical Performance
Resolution 3.5 lp/mm
Energy Range 40-160 KV
Lag   0.8% @ 1st frame
Dynamic Range   ≥86 dB
Sensitivity   540 lsb/uGy
SNR   48 dB @(20000lsb)
MTF   72% @(1 lp/mm)
44% @(2 lp/mm)
25% @(3 lp/mm)
DQE 64% @(0 lp/mm)
41% @(1 lp/mm)
28% @(2 lp/mm)
Mechanical
Dimension(H x W x D)   1125 x 486.2 x 15 mm
Weight   13.2 Kg

Sensor Protection Material 

Carbon Fiber
Housing Material   Aluminum Alloy
Environmental
Temperature Range  10~35℃(operating); -10~50℃(storage)
Humidity 30~70% RH(non-condensing)
Vibration IEC/EN 60721-3 class 2M3(10~150 Hz,0.5 g)
Shock IEC/EN 60721-3 class 2M3(11 ms,2 g)

Dust and Water Resistant

IP54
Power
Supply  100~240 VAC
Frequency 50/60 Hz
Consumption  18W
Application
Medical Suitable for full spine X-ray
Mechanical Dimension
Whale43100PSM 4 Whale43100PSM 5

Our products are greatly acknowledged and reliable by users and may fulfill repeatedly shifting financial and social wants for Top Quality Fixed X-ray Grid Jpi Fixed X-ray Grid Medical Lead Anti Scatter Grid X Rays, Aggressive selling price with superior quality and satisfying services make us earned far more consumers.we wish to work along with you and look for common improvement.
Top Quality China X-ray Grid and X Ray Grid, If any item be of interest to you, make sure you let us know. We’ll try our best to satisfy your requirements with high quality solutions, the best prices and prompt delivery. You should feel free to contact us at any time. We’ll reply you when we receive your inquiries. Please note that samples are available before we start our business.